+7 777 202 43 24 Delivery across KazakhstanDelivery across KZ Call me back Download price list Sign in·Register USD 451,87 · RUB 5,53
RU KZ EN
Home/ Catalogue/ ТОЛ 10/ Current transformers ТОЛ-10-1000/5

Current transformers ТОЛ-10-1000/5

SKU: ask the manager In stock in Almaty
104 200 ₸
Price incl. VAT, per pcs Almaty warehouse
Register to get your personal price
1
Get a quote in PDF
ManufacturerAlageum Electric
Country of originKazakhstan
Voltage10 kV
Rated current200 A
Mass22 kg
Frequency60 Hz
  • Official distributor, manufacturer's warranty
  • Passport and certificates on request
  • Delivery across Kazakhstan

Delivery across Kazakhstan by freight carriers; lead time and cost from a manager.

Current transformers The transformers are intended for transmitting the measurement information signal to measuring instruments and to protection and control devices, and for isolating secondary circuits from high voltage in indoor and outdoor AC switchgear assemblies (КРУ, КРУН and КСО) for a voltage class of up to 10 kV at a frequency of 50 or 60 Hz. Transformers for differential protection are supplied to special order. The transformers are manufactured in versions "У" and "Т", placement category 2 according to ГОСТ 15150, and are intended for operation under the following conditions: altitude not more than 1000 m above sea level; the ambient temperature, taking into account air overheating inside the КРУ, is given in Table 1; the environment is non-explosive and free of dust, chemically active gases and vapours in concentrations that destroy metal coatings and insulation; operating position - any. The transformers are fitted with transparent protective covers for separate sealing of the secondary terminalsPatent protection Patent for invention No. 2089955. Table 1. Technical data Climatic version Operating temperature value °C lower upper operation transportation operation transportation У2 -45 -50 50 50 Т2 -10 -50 55 60 Table 2 Transformer type Rated primary current, A B, mm H, mm h, mm Fig. Weight, kg ТОЛ-10-I-1 5-400 40 224 26 2,4 20±1 500-800 32 1000-2000 60 36 ТОЛ-10-I-2 5-400 40 26 1,3 500-800 32 1000-2000 60 36 ТОЛ-10-I-3 30, 40, 50, 75, 80, 100, 150 40 18 2,4 20±1 ТОЛ-10-I-4 1,3 ТОЛ-10-I-5 100, 150, 200 40 234 22 2,4 ТОЛ-10-I-6 1,3 ТОЛ-10-I-7 50-800 40 224 20 2,6 20±1 ТОЛ-10-I-8 1000-2000 60 1,5 Table 3 Parameter Rating Design version number 1 or 2 3 or 4 5 or 6 7 or 8 Rated voltage, kV 10 or11* Highest operating voltage, kV 12 Rated AC frequency, Hz 50 or 60* Rated secondary current, A 1 or 5 Rated primary current, A 5,10,15,20,30, 40,50,75,80, 100,150,200, 300,400,500, 600,750,800, 1000,1200, 1500,2000 30,40, 50,75, 80,100, 150 100,150, 200 50,75,100, 150,200, 300,400, 500,600, 750,800, 1000,1200, 1500,2000 Number of secondary windings 2 3 Accuracy class of the measuring secondary winding at rated primary current, A: 5-400 500-1500 0,2;0,2S;0,5;0,5S or 1 0,2;0,2S;0,5;0,5S Accuracy class of the protection secondary winding 5P; 10P Rated secondary burden at power factor cosφ = 0,8 VA: - of the measuring secondary winding - of the protection secondary winding up to 30** 15 Rated accuracy limit factor of the protection secondary winding, at least 10 Rated instrument security factor of the measuring winding in accuracy class 0,5 and 1, not more than, at rated primary current, A, 500; 700 5-300; 600; 1000 1200 80; 400; 800;1500 11 13 14 16 Instrument security factor of the measuring winding in accuracy class 0,2; 0,5S; 0,2S, not more than 10 One-second rated short-time thermal current, kA, at rated primary current, A: 5 10 15 20 30 40 50 75 80 100 150 200 300,400 500-2000 0,4 0,78 1,2 1,56 2,5 3,0 5 5,85 6,23 10 12,5 20 31,5 40 - - - - 3,2 4,3 8 20 20 20 20 - - - - - - - - - - - - 31,5 31,5 31,5 - - - - - - - - 5,0 5,85 - 10 12,5 20 20 40 Rated dynamic current, kA, at rated primary current,A: 5 10 15 20 30 40 50 75 100 150 200 300,400 500-2000 1 1,97 3 3,93 6,25 7,56 12,8 14,7 25,5 31,8 51 81 102 - - - - 8 10 20 51 51 51 - - - - - - - - - - - 81 81 81 - - - - - - - - 12,8 14,7 25,5 31,8 51 51 102 Test voltage, kV: power-frequency lightning impulse 42 75 Note: * - for export deliveries only ** - the burden value is specified in the order, for example "ТОЛ-10-I-2-0,5/10Р-200/5 15ВА"; if the burden is not stated in the order, the transformer is manufactured by default with a burden of 10 VA. Calculated values of the rated accuracy limit factor of the protection secondary winding as a function of the rated secondary burden in accuracy class 10P for ТОЛ-10-I current transformers. Table 4. For design versions ТОЛ-10-I-1,2,3,4,5,6 Rated secondary burden, VA 3 5 10 15 20 30 40 50 Transformation ratio Rated accuracy limit factor 5 - 300/5 27 20 12 10 7 5 4 3 80, 200, 400/5 27 21 14 10 8 6 4 3,5 500/5 24 20 13 10 8 5 4 4 600/5 26 21 15 10 9 7 5 4 750/5 27 23 16 13 10 8 6 5 800/5 28 23 17 10 11 8 6 5 1000/5 20 17 13 10 9 7 5 5 1200/5 20 17 13 10 9 7 5 5 1500/5 21 18 14 10 10 8 6 5 2000/5 21 17 14 10 11 9 7 6 Table 5. For design versions ТОЛ-10-I-7,8 Rated secondary burden, VA 3 5 10 15 20 30 40 50 Transformation ratio Rated accuracy limit factor 50 - 600/5 24 19 13 10 8 6 4 4 750/5 26 21 15 11 9 7 5 4 800/5 26 21 15 10 10 7 5 5 1000/5 20 16 12 10 8 6 4 4 1200/5 21 17 13 10 9 6 5 4 1500/5 21 18 14 10 10 8 6 5 2000/5 18 15 12 10 9 7 6 5 About the company Казтрансформатор LLP Казтрансформатор LLP is a fast-growing electrical engineering company focused on the turnkey delivery of construction, reconstruction and modernisation projects for power facilities in the Republic of Kazakhstan. Our mission is to understand the capabilities and needs of our customers and to provide solutions and equipment of high quality and reliability using modern technologies. We are an official representative of the Alageum Electric brand and hold the supporting certificates of conformity, CT KZ certificates and manufacturers' warranties. Key advantages of working with our company In-house production facilities. Orders of any complexity fulfilled. Affordable prices. High product quality and reliability. Modern high-tech equipment. Shortest possible lead times. Product warranty of up to 5 years 18 years on the market. Delivery throughout Kazakhstan, as well as to Kyrgyzstan, Russia and Uzbekistan. The transformer substations we manufacture are coated with "moisture-resistant powder paint". How to order Orders are placed by e-mail to the address given on the website or by phone. Full prepayment of the order. Delivery by transport companies or collection from the company's warehouse.

Get a quote

A quote with prices and terms is generated instantly — you can download the PDF and send it to your manager on WhatsApp.

Frequently bought together

Similar products

Whole category →
104 200 ₸ In stock in Almaty
Quick price request Current transformers ТОЛ-10-1000/5

Leave your name and phone — a manager will call you back with the price and lead time during business hours.